Search Content

Use the search bar above, explore content using the categories below, or log in to find your favorites.

Create An Account

Thank you for choosing to create an account with us.

Please note that creating an account is optional, but helps us better tailor the content we show you.


Please enter your email address and choose a password.

By creating an account, you agree to our Terms and Conditions and our Privacy Policy

Log in

Tell us a little about yourself


Choose Areas of Interest

Please tell us a little more about your profession.

This is optional, but lets us better tailor content to your specific interests.


You can read our policy on data collection and privacy here.

Channels that Interest You

Finally, check which channels interest you so you can see more relevant content. Choose as many as you like. You can also come back here and edit these settings later.


Share Content

Share our content with your friends and colleagues using the links below.


Sign up Forgot your password?
Home High Performance HVAC - VRF & Part Loads - Part 2

In a four-part series on high performance HVAC, VRF, here is part two that concentrates on part loads. In this video, Kristof Irwin begins by defining the forces that establish variable loads, from sun and wind to extreme rain and cold, these variable forces have a major impact.

From a range of human body temperature, we can figure a range of acceptable indoor temperatures. Given a range of outdoor conditions, using a simple formula, it's easy to identify the cooling load and the heating load for the mechanical equipment. There are three types of loads, extreme load, design load, and part load. Although builders will often concentrate on extreme load and design load, the part load is critical, and it exists throughout the vast majority of hours in the year.

The discussion, easily caught in the video by a series of slides, but arrives at the question, if you are designing the tool to offset a varying cooling load, the tool would be difficult to define. However, the goal is to match capacity to load. For the home, the functional need is to deliver comfort by delivering varying and incremental amounts of heating and cooling. Comparing that need to standard technology, the majority of the market in the U.S. is based on a single compressor that goes from 0% at off to 100% at on. There are also dual-stage and unloading compressors so that you can move from 0% to 50% to 100%, or 0% to 67% to 100% respectively. So, in effect, you have two speeds. Comparing the previous versions with variable capacity, using an inverter scroll compressor, you can move from 0% to 4-30% to 100%. So, you are better able to match, with this compressor," what is happening outside.

Showing result 1 to 8 of 45