Search Content

Use the search bar above, explore content using the categories below, or log in to find your favorites.

Create An Account

Thank you for choosing to create an account with us.

Please note that creating an account is optional, but helps us better tailor the content we show you.


Please enter your email address and choose a password.

By creating an account, you agree to our Terms and Conditions and our Privacy Policy

Log in

Tell us a little about yourself


Choose Areas of Interest

Please tell us a little more about your profession.

This is optional, but lets us better tailor content to your specific interests.


You can read our policy on data collection and privacy here.

Channels that Interest You

Finally, check which channels interest you so you can see more relevant content. Choose as many as you like. You can also come back here and edit these settings later.


Share Content

Share our content with your friends and colleagues using the links below.


Sign up Forgot your password?
Home 5 Major Changes To Buildings In The Last 50 Years

I saw this video of Joe Lstiburek (who is well regarded as one of the nation’s top Building Science experts) and wanted to pass it along.  He’s discussing the five fundamental changes that have occurred in the way we build buildings from 50 years ago to today.  
Here’s my quick executive summary:

1.  Increase Thermal Resistance – Need to increase thermal resistance through the roof, walls, building slabs, etc.  We can do so by using better materials, clever design, and by understanding the physics behind it and dealing with it.
 
2.  Changing of the permeability of the linings that we put on the inside/outside of the building enclosure – Over the years, we have gone from plywood to OSB, which doesn’t breathe.  We also started using insulating sheathing made of plastics, vinyl wall paper, and foil face fiberglass batts, which also don’t breathe.  We can’t put vapor barrier on both sides of the building assembly.  The solution is to control the permeability of the linings that we use.
 
3.  Water & mold sensitivity of out building materials have been going up – Mold is a water problem.  No water, no mold.  Over the years, we have gone from trees to lumber to plywood to OSB to hardboard to particle board to drywall.  When you go from timber to engineered materials, the processing makes the materials more mold and water sensitive.
 
4.  Ability of the building enclosure to store and redistribute moisture has been going down –  A 1950’s house has a hydric buffer capacity of 50 gallons, which consists of wood framing and plywood sheathing.  The same size house with steel studs and gypsum sheathing will have a HBC of around 3-5 gallons.  In the last century, the HBC has decreased significantly due to our choices of materials.
 
5.  Now have complex three-dimensional airflow networks that inadvertently couple the building enclosure to the breathing zone of the occupied space – 
Engineers/Architects/Contractors have essentially turned the building enclosure into the contaminant and turned the mechanical system into the contaminant interstate that couples the enclosure to the breathing zone of the occupied space.
 
 